Our Products

10 KVA - 2000 KVA

We are a manufacture of 10 KVA to 2000 KVA (3 phase input & 3 phase output) double conversion On-Line UPS with an isolation transformer at Output. The Load is supplied continuously by the inverter with clean, stabilized and regulated sine wave output power. Input & Output filters increase the immunity of load from power disturbances and surges.

ON Line - Double Conversion Online UPS is useful for mission critical applications like IT, Call Centers, Hospitals, and Industrial Automation etc. Thanks to state-of-the-art microprocessor / DSP based outstandiing advanced technology design. ON Line- Double Conversion Online UPS can be used for monitoring various parameters of the UPS and also can be useful for remote monitoring / control on the web by adding SNMP Card.

ONLINE UPS
Servo Stabilizer
TECHNICAL SPECIFICATIONS
INPUT
RATING VOLTAGE
380/220, 400/230, 480/277,
208/120 93-phase,
4-wire plus ground) V
VOLTAGE RANGE
±20 %
INPUT CURRENT HARMONIC DISTORTION
<3 (with optional rectifier or filter) %
RATING FREQUENCY
50/60 ± 5% Hz
OUTPUT
VOLTAGE
220,230,240 (1-phase, 2-wire plus ground) V

220,230,240 (1-phase, 2-wire plus ground) V
380/220, 400/230, 415/240, 480/277, 208/120 (3-phase, 4-wire plus ground)

VOLTAGE HARMONIC DISTORTION
≤ 3 % (linear load)
VOLTAGE REGULATION
Static
± 1%
Dynamic
± 5%
FREQUENCY
50/60 Hz
FREQUENCY REGULATION
Interior Oscillator
± 0.01%
Synchronized
±1%
OVERLOAD
≤ 110% 60 minutes, 110~125% : 10 minutes; 126~150% : 1 minute
DISPLAY
LED
AC mains normal, reserve source normal, rectifier, inverter, static switch, battery status
LCD
Input bypass inverter, output & battery voltage,
current and frequency load level, abnormal message
REMOTE
Monitor
Multi-unit monitor, graphic display, history data statistics
Control
Inverter horns remote control, password setting,
fault information reading, remote panel
OTHERS
Communication Interface
Standard: RS232 x 1, RS485 x 1,
status dry contact output x 6 Option : SNMP card, Modbus card,
Ethernet port, remote panel
Parallel Redundancy
Yes (up to 8 UPS)
Emergency Power off
Yes (local & remote)
Multi-Speed Fan control
Yes (10 levels)
SRAM
Yes (500 event logs)
Parameter settings
Yes
Battery start
Yes (option)
Input Harmonic Improvement
Harmonic filter and 12-pulse rectifier (option)
OVERALL
Economic
> 97,  > 97.5%
Normal
90, 91, 91.5, 92, 92.5%
Transfer time
0 ms
Temperature
0~40 K
Relative humidity
90% (Non-condensing)
Audible Noise (at 1.5m distance)
≤60, ≤65, ≤68, ≤72, ≤77 dBA
Applications
H-class galvanic Isolation
Load bus synchronization
Intelligent charger
                                                                